Window Condensation Calculator

Will your windows be wet tomorrow morning? Enter the room temperature, the humidity from your hygrometer, the outdoor temperature and your window type. The calculator compares the dew point of your indoor air with an estimate of how cold the glass gets.

By HOMENVIRO Editorial Team · Published November 25, 2026

Check your window

Unlikely on the glass

The glass should stay above the dew point. If it still gets wet, the window may be colder than this estimate (for example behind a curtain or blind) or the room humidity rises at night.

Dew point of indoor air
46°F
Estimated glass temperature
52°F
Margin
+6°F
Keep humidity below
46%

At these temperatures, keeping indoor humidity below about 46% should keep this window dry, including its colder edges.

Highest humidity before condensation at 68°F inside and 25°F outside
Window typeGlass temp.Keep humidity below
Single glazing36°F24%
Older double glazing (air-filled)52°F46%
Modern double glazing (low-E, gas-filled)59°F60%
Triple glazing64°F70%
01

How the calculation works

Every parcel of indoor air has a dew point: the temperature at which its water vapor starts to turn back into liquid. The calculator finds it from your temperature and humidity using the standard Magnus formula. It then estimates the inside temperature of the glass from the indoor and outdoor temperatures and a typical heat-loss value (U-value) for your window type. If the glass is colder than the dew point, water forms on it.

02

Why we add a safety margin

The estimate describes the centre of the glass. The bottom edge, the corners, the spacer bar and especially metal frames are colder, and curtains or blinds trap cold air against the window at night. To reflect that, the “keep humidity below” figure assumes the coldest parts are about 5°F (3°C) colder than the centre. Treat it as a practical target, not a guarantee.

03

Use real readings, at the right time

Measure humidity with a hygrometer in the room, away from the kettle, shower and window, and use the coldest outdoor temperature expected overnight. Bedrooms often rise several percentage points overnight as people breathe, so a reading taken at bedtime with the door closed is more useful than one from the afternoon. Our 7-day moisture log helps you record a pattern.

04

What to do with the result

If condensation is likely, lower the room’s humidity with extractor fans, trickle vents, brief airing and, where needed, a dehumidifier; see humidifier or dehumidifier in winter? Open curtains during the day so the glass can warm, and wipe the glass and sill dry on wet mornings to prevent mold on the window sill. If one window stays wet while others in the same room are dry, check its seals and frame.

CONDENSATION QUESTIONS

Common questions

Why do my windows get wet when the humidity is only 40%?

Because the glass can be far colder than the room. At 68°F (20°C) and 40% humidity the dew point is about 43°F (6°C). On a freezing night, single glazing and the edges of older double glazing can easily fall below that, so water condenses even though 40% sounds low.

What indoor humidity should I aim for in winter?

EPA suggests 30–50% indoors. In cold weather the right number depends on your windows: the colder it is outside and the less insulated the glass, the lower the humidity needs to be to keep it dry. Use the table in the calculator to see the limit for tonight’s temperature.

Why is the bottom of the window wetter than the middle?

The edges of the glass and the frame lose heat faster than the centre, and cold air sinks down the glass. The calculator estimates the glass centre and adds a safety margin for those colder edges, which is why its “keep humidity below” figure is lower than the dew point alone suggests.

Does condensation between the panes mean the same thing?

No. Fog or water trapped between the panes of a sealed double- or triple-glazed unit means the seal has failed. Lowering room humidity will not clear it; the glazing unit usually needs repair or replacement.

PART OF THE HOME MOISTURE GUIDESee every condensation, damp and mold guide in one place →

METHOD & SCOPE

Dew point uses the Magnus approximation (coefficients 17.62 and 243.12°C). Glass temperature uses a steady-state estimate with a standard inside surface resistance of 0.13 m²K/W and typical whole-window U-values: single 5.8, older double 2.8, modern low-E double 1.6 and triple 0.8 W/m²K. Real windows vary with frame material, wind, sun, curtains and airflow. Humidity guidance follows the EPA indoor-air guide and EPA’s guide to mold, moisture and your home. This tool is an estimate for everyday decisions, not a building survey.